ASCE 7-22 Seismic Design Category: How to Determine SDC from SDS, SD1, and S1
The Seismic Design Category comes from three USGS values and the Risk Category. Here is the ASCE 7-22 Section 11.6 lookup step by step: the mapped S1 ≥ 0.75 g rule for SDC E and F, Tables 11.6-1 and 11.6-2, the exceptions that let you use the short-period table alone, and three worked US examples.
What the Seismic Design Category is
The Seismic Design Category (SDC) is a letter from A to F that ASCE 7-22 Section 11.6 assigns to every building and structure from two things: its Risk Category and the severity of the design earthquake ground motion at the site. It controls permitted systems and height limits, analysis procedures, detailing and irregularity limits, and how much of Chapter 13 applies to nonstructural components.
The four inputs: Risk Category, mapped S1, SDS, and SD1
- Risk Category (I, II, III, or IV) from ASCE 7-22 Table 1.5-1, based on the occupancy and the consequence of failure. Essential facilities such as hospitals and fire stations are typically Risk Category IV.
- Mapped S1: the MCER spectral response acceleration at a 1-s period, in g, from the USGS Seismic Design Geodatabase (Section 11.4.3). This is the mapped value for the reference site condition, not the design value.
- SDS and SD1: the design spectral response accelerations at short periods and at 1 s (Section 11.4.4), where SDS = (2/3) SMS and SD1 = (2/3) SM1.
The seismic importance factor Ie (Table 1.5-2) is not an input. It scales seismic forces later in the design; it does not assign the SDC.
How ASCE 7-22 site class and multi-period spectra feed SDS and SD1
ASCE 7-22 uses nine site classes, A, B, BC, C, CD, D, DE, E, and F, defined in Chapter 20 by the average shear-wave velocity of the upper 100 ft. The intermediate classes and the default site class are covered in our public ASCE 7-22 site class & Vs30 guide.
The ASCE 7-22 general procedure has no Fa and Fv tables: the USGS ASCE 7-22 web service (and the ASCE Hazard Tool built on it) returns SMS, SM1, SDS, and SD1 already computed for the site class. Our USGS Seismic Design Geodatabase guide shows the request and the response fields.
Whether you design with the multi-period spectrum (Section 11.4.5.1) or the two-period spectrum (Section 11.4.5.2), the SDC is set by the scalar SDS and SD1. Site Class F is the exception to the whole lookup: the USGS service doesn't return values for F, and F sites need a site response analysis in accordance with Section 21.1, which Section 11.4.7 also requires, except where Section 20.2.1 waives that analysis (including liquefiable soils when the fundamental period is 0.5 s or less, and certain clay profiles in Seismic Design Categories A and B).
Step 1: check mapped S1 first (SDC E and F)
Before you open either table, look at the mapped 1-s value S1:
- If S1 ≥ 0.75 g and the structure is Risk Category I, II, or III, the SDC is E.
- If S1 ≥ 0.75 g and the structure is Risk Category IV, the SDC is F.
Tables 11.6-1 and 11.6-2 by themselves never go higher than D; E and F come only from this rule.
Two common mistakes: first, the trigger is mapped S1, not the design value SD1. Second, the rule is not a "near-fault" checkbox. ASCE 7-22 Section 11.4.1 separately defines near-fault sites: within 9.5 mi (15 km) of the surface projection of a known active fault capable of Mw 7 or larger, or within 6.25 mi (10 km) of one capable of Mw 6 to under 7. Faults slipping less than 0.04 in. per year don't count, and the surface projection doesn't include portions of the fault at depths of 6.25 mi (10 km) or greater (Section 11.4.1 Exceptions 1 and 2). It doesn't change the SDC letter. If you need fault distances, see our distance to active faults guide.
Step 2: Tables 11.6-1 and 11.6-2, then take the more severe
If S1 is less than 0.75 g, assign a category from each table for the structure's Risk Category, and use the more severe of the two, irrespective of the fundamental period T. The thresholds below are those of ASCE 7-22 Tables 11.6-1 and 11.6-2.
| Value of SDS | Risk Category I, II, or III | Risk Category IV |
|---|---|---|
| SDS < 0.167 | A | A |
| 0.167 ≤ SDS < 0.33 | B | C |
| 0.33 ≤ SDS < 0.50 | C | D |
| 0.50 ≤ SDS | D | D |
| Value of SD1 | Risk Category I, II, or III | Risk Category IV |
|---|---|---|
| SD1 < 0.067 | A | A |
| 0.067 ≤ SD1 < 0.133 | B | C |
| 0.133 ≤ SD1 < 0.20 | C | D |
| 0.20 ≤ SD1 | D | D |
Risk Category IV steps up one letter in the middle rows (B to C, and C to D) but matches Risk Categories I to III at the bottom (A) and the top (D) of each table. Also note that the Chapter 19 soil–structure interaction provisions can't be used to modify the spectral values used to determine the SDC. If your copy of the standard shows a blank in the last Risk Category IV cell of Table 11.6-2, that is a known misprint: ASCE 7-22 errata (page E2, for printed page 108) says the table is missing the Risk Category IV entry for 0.20 ≤ SD1 and that it should be D.
Section 11.6 exceptions: when Table 11.6-1 alone is permitted
Short-period exception
Where S1 is less than 0.75 g, Section 11.6 permits the SDC to be determined from Table 11.6-1 alone when all of these apply:
- In each of the two orthogonal directions, the approximate fundamental period Ta (Section 12.8.2.1) is less than 0.8 Ts, with Ts from Section 11.4.5.
- In each of those directions, the fundamental period used to calculate story drift is less than Ts.
- Equation (12.8-2) is used to determine the seismic response coefficient Cs.
- The diaphragms are rigid per Section 12.3, or, for diaphragms that are not rigid, the horizontal distance between vertical elements of the seismic force-resisting system does not exceed 40 ft.
It helps short, stiff buildings where SD1 pushes the category up but SDS does not.
Simplified design procedure (Section 12.14)
Where the simplified alternative procedure of Section 12.14 is used, Section 11.4.4 takes SDS from Section 12.14.8.1, and Section 11.6 permits the SDC to be determined from Table 11.6-1 alone with that SDS, except that where S1 ≥ 0.75 g the SDC is E. Section 12.14.1.1 limits the procedure to Risk Category I or II structures, sites other than Site Class E or F, no more than three stories above grade plane, and the bearing-wall and building-frame systems of Table 12.14-1, plus layout and regularity conditions. Because Risk Categories III and IV are excluded, this path never leads to SDC F.
Worked examples in US units
These values were returned by the USGS ASCE 7-22 web service on November 16, 2026, for Site Class D. Re-pull them for your own project.
Example 1: Dallas, Texas (32.7767, −96.7970), Site Class D
SS = 0.12 g, S1 = 0.059 g, SMS = 0.16 g, SM1 = 0.13 g, SDS = 0.11 g, SD1 = 0.084 g.
Step 1: S1 = 0.059 g < 0.75 g, so SDC E and F do not apply.
Table 11.6-1: SDS = 0.11 < 0.167, so A for every Risk Category.
Table 11.6-2: 0.067 ≤ 0.084 < 0.133, so B for Risk Category I, II, or III, and C for Risk Category IV.
More severe of the two: SDC B for a Risk Category II office, and SDC C for a Risk Category IV essential facility on the same site.
Risk Category II → B · Risk Category IV → C (the USGS service returned the same letters)
SD1 governs, and Risk Category changes the letter at identical accelerations. If the structure met every short-period exception condition, Table 11.6-1 alone would give A; the lookup can't check that for you.
Example 2: Seattle, Washington (47.6062, −122.3321), Site Class D
SS = 1.56 g, S1 = 0.66 g, SDS = 1.15 g, SD1 = 0.92 g.
S1 = 0.66 g is high but still below 0.75 g, so the tables govern. SDS ≥ 0.50 and SD1 ≥ 0.20, so both tables give D for every Risk Category, even though SD1 is above 0.75 g. It is not SDC E.
Risk Category II → D · Risk Category IV → D
Example 3: Parkfield, California (35.8997, −120.4320), Site Class D
SS = 2.05 g, S1 = 0.78 g, SDS = 1.28 g, SD1 = 1.70 g.
The tables would give D, but S1 = 0.78 g ≥ 0.75 g, so the S1 rule governs. Section 11.8.1 also restricts siting SDC E and F structures where there is a known potential for an active fault to rupture the ground surface at the structure.
Risk Category II → E · Risk Category IV → F
Get the Seismic Design Category from CalcGeo's ASCE 7-22 tool
CalcGeo's ASCE 7-22 seismic tool looks up the USGS values for your latitude, longitude, site class, and Risk Category and shows SDS, SD1, SMS, SM1, SS, S1, PGAM, the spectra, and the Seismic Design Category, with a report-ready write-up.
For the SDC, it reports the USGS sdc value as returned for the Risk Category you chose. It does not evaluate the Section 11.6 short-period exception or the Section 12.14 path; those need structural period, system, and diaphragm information, so the engineer still has to check them. It doesn't return values for Site Class F. The tool is free with email sign-in.
See the ASCE 7-22 tool: details & FAQ →
Free The ASCE 7-22 seismic calculator is free with email sign-in. No card, no trial clock.
Already subscribed? Sign in. New accounts use the same email-link sign-in.
Frequently asked questions
How do you determine the Seismic Design Category in ASCE 7-22?
First check the mapped 1-s spectral acceleration S1. If S1 is 0.75 g or greater, assign Seismic Design Category E for Risk Category I, II, or III, and F for Risk Category IV. Otherwise, look up SDS in Table 11.6-1 and SD1 in Table 11.6-2 for the Risk Category, and assign the more severe of the two results, irrespective of the building period. SDS and SD1 are two-thirds of the site-adjusted SMS and SM1 values from the USGS Seismic Design Geodatabase for the ASCE 7-22 site class.
When is a building assigned Seismic Design Category E or F?
Under ASCE 7-22 Section 11.6, mapped S1 ≥ 0.75 g assigns SDC E to Risk Category I, II, or III structures and SDC F to Risk Category IV structures. The trigger is the mapped 1-s parameter S1, not SD1, and it is not the same thing as the Section 11.4.1 near-fault site definition. Tables 11.6-1 and 11.6-2 by themselves only go as high as SDC D.
Can I determine the Seismic Design Category from the short-period table alone?
Only under the Section 11.6 exceptions. If S1 is less than 0.75 g and the structure meets all four short-period conditions (Ta < 0.8 Ts and drift period < Ts in both directions, Cs from Equation (12.8-2), and rigid diaphragms or vertical-element spacing ≤ 40 ft), Table 11.6-1 alone may be used. The Section 12.14 simplified procedure (Risk Category I or II, three stories or less) has a similar permission using its own SDS, except that if S1 ≥ 0.75 g the category is E. Otherwise the more severe of Tables 11.6-1 and 11.6-2 governs.
Does the importance factor or soil-structure interaction change the SDC?
No. The seismic importance factor Ie scales design forces; it does not assign the category. Risk Category, mapped S1, SDS, and SD1 do. ASCE 7-22 also says the Chapter 19 soil-structure interaction provisions shall not be used to modify the spectral values used to determine the SDC.
Does this apply to my building code?
The tool follows ASCE 7-22 only, so the SDC follows Section 11.6 as described here. Where the governing building code adopts ASCE 7-22 for seismic loads, the same rules apply. Check the governing local building code, its adopted edition, and any amendments, since local codes may add requirements.
Is a calculator result enough for the report?
No. A lookup gives the mapped and design values and the category for the inputs you chose; a licensed engineer still has to confirm the site class, the Risk Category, any exceptions, and whether a site-specific ground motion procedure under ASCE 7-22 Chapter 21 is required, as it is for Site Class F except where Section 20.2.1 waives the site response analysis (including liquefiable soils when T is 0.5 s or less, and certain clays in SDC A and B).
Related: ASCE 7-22 site class & Vs30 guide · USGS Seismic Design Geodatabase guide · Distance to active faults · ASCE 7-22 seismic tool: details & FAQ · All tools · All public guides